Page 34 - Hilti (HK) – Product Catalogue
P. 34
ANCHORING SYSTEMS 8
Undercut anchor HDA-P
BASE MATERIALS Approvals
● Concrete (cracked) BZS D 09-601 for HDA self-cutting undercut
BZS/shock
● Concrete (uncracked) anchor
ETA 99/0009 for HDA self-cutting undercut
ETA
anchor (ETAG 001-03, Option 1)
APPLICATIONS Approvals and test reports may apply to selected products only. Please refer
● Safety-relevant, heavy-duty fastenings for all dynamic loading to the documents for details.
(shock, seismic and fatigue) in cracked or uncracked concrete,
including applications in nuclear power plants
● Fastenings to support heavy pipes, safety barriers, industrial
machines, crane rails, dorm structures, crash barriers, roof
fixings, elevator tracks, bridge retrofitting etc.
ADVANTAGES
● Self-undercutting facilitates fast and reliable installation
without the need for a separate undercutting tool or additional
operations
● Combines the advantages of a post-installed mechanical
anchor, i.e. flexibility and immediate loading, with the
performance of a cast-in-place headed stud
● Close spacing and small edge distance thanks to low expansion
forces These are abbreviated instructions which may vary according to the application.
Technical data
Material composition (Galvanized) Bolt: steel, 8.8 grade,
zinc-plated (min. 5 μm);
(Sherardized) Bolt, 8.8 grade,
sherardized (min. 53 μm);
(Stainless steel) Steel, A4 (SS316)
8
Head configuration Externally threaded
Type of fastening Through-fastening
IBC compliance IBC 2003, IBC 2006, IBC 2009,
IBC 2012
Additional product information Meets approval requirements when
installed using the specified stop
drill bit, setting tool and rotary
hammer
Technical data
Recommended load (kN), non-cracked concrete at 25N/mm², safety factor(γ)=3
Model Size M10 M12 M16 M20
HDA-T/ Tensile Load, Nrec 15.3 22.3 42.0 64.0
HDA-TF Shear Load, Vrec 7.3 10.0 20.6 30.6
Tensile Load, Nrec 15.3 22.3 42.0 -
HDA-TR
Shear Load, Vrec 7.6 11.3 21.0 -
Recommended load (kN), cracked concrete at 25N/mm², safety factor(γ)=3
Model Size M10 M12 M16 M20
HDA-T/ Tensile Load, Nrec 8.3 11.6 25.0 31.6
HDA-TF Shear Load, Vrec 7.3 10.0 20.6 30.6
Tensile Load, Nrec 8.3 11.6 25.0 -
HDA-TR
Shear Load, Vrec 7.6 11.3 21.0 -
Remarks:
1) All the data applies to no edge distance, spacing and other influences
2) HDA M20: only available in galvanized steel version
3) For detail design method and cracked concrete information, please refer to Fastening
Technology Manual
Customer Hotline: Hong Kong 8228 8118, Macau 00800 8228 8118 Email: hksales@hilti.com